Measuring Probes for Magnetic Field Measuring

分享到:
点击次数:3303 更新时间:2023年04月11日13:46:27 打印此页 关闭

Measuring Probes for Magnetic Field Measuring

Measuring Probes for the Magnetic Field Meters / Gaussmeter MP-1000, MP-2000 and MP-5000

Measuring direction for Magnetic Field Measuring

Measuring Probes for Magnetic Field Measuring

Axial Field Probe P-A2

Measuring range: 0-20,000 A/cm / 0-20,000 Gauss / 0-2 T
Hall Sensor distance: 2.0 mm
Total length of the probe: 150 mm
Length of the probe handle: 85 mm
Diameter of the probe tube: 7.5 mm
Magnetic Field Meter probes

Tangential Field Probe P-T2

Measuring range: 0-20,000 A/cm / 0-20,000 Gauss / 0-2 T
Hall Sensor distance: 0.9 mm
Probe thickness: 1.7 mm
Total length of the probe: 155 mm
Length of the probe handle: 85 mm
Width of the probe tube: 5.5 mm
Magnetic Field Meter probes

Flexible Reed Probe P-Z2

Measuring range: 0-20,000 A/cm / 0-20,000 Gauss / 0-2 T
Hall Sensor distance: 0.4 mm
Probe thickness: 0.7 mm
Total length of the probe: 150 mm
Length of the probe handle: 85 mm
Width of the probe reed: 4.3 mm
Magnetic Field Meter probes

Angular Axial Probe P-W2

Measuring range: 0-20,000 A/cm / 0-20,000 Gauss / 0-2 T
Total length of the probe: 150 mm
Length of the probe handle: 85 mm
Magnetic Field Meter probes

Axial Field Probe P-A4

Measuring range: 0-40,000 A/cm / 0-40,000 Gauss / 0-4 T
Hall Sensor distance: 2.0 mm
Total length of the probe: 150 mm
Length of the probe handle: 85 mm
Diameter of the probe tube: 7.5 mm
X
Magnetic Field Meter probes

Tangential Field Probe P-T4

Measuring range: 0-40,000 A/cm / 0-40,000 Gauss / 0-4 T
Hall Sensor distance: 0.9 mm
Probe thickness: 1.7 mm
Total length of the probe: 155 mm
Length of the probe handle: 85 mm
Width of the probe tube: 5.5 mm
X
Magnetic Field Meter probes

Flexible Reed Probe P-Z4

Measuring range: 0-40,000 A/cm / 0-40,000 Gauss / 0-4 T
Hall Sensor distance: 0.4 mm
Probe thickness: 0.7 mm
Total length of the probe: 150 mm
Length of the probe handle: 85 mm
Width of the probe reed: 4.3 mm
X
Magnetic Field Meter probes

Tangential Field Probe P-T4A Analog Output

Measuring range: 0-40,000 A/cm / 0-40,000 Gauss / 0-4 T
Plugs: for probe cable and for BNC cable as output to an oscilloscope
Virtual baseline: 0 mT = 1.8 V
Measuring range 1: 0,1 mT - 80 mT = ± 900 mV
Measuring range 2: 1 mT - 4000 mT = ± 700 mV
Total length of the probe: 155 mm
Length of the probe handle: 85 mm
Width of the probe tube: 5.5 mm
X
Magnetic Field Meter probes
All probes are of plug-in design
1 A/cm = 0.1 kA/m = 1.256 Gauss = 1.256 Oersted = 0.1256 mT
上一条:Magnetic Field Meter / Gaussmeter MP-5000 下一条:Coating Thickness Meter TOP-CHECK Ferro-1000